[rc3r] Re: Train Station Modules

  • From: Peter Condro <pcondro@xxxxxxxxx>
  • To: rc3r@xxxxxxxxxxxxx, kevopelli@xxxxxxxxx
  • Date: Sat, 22 Apr 2017 14:17:18 -0400

Kevin….that can be done…..the issue is the placement of the overhead 
station……you don’t want it over a switch…….let me play with it.
Peter



On Apr 22, 2017, at 11:16 AM, kevopelli@xxxxxxxxx wrote:

How about something simpler, like this?
Tom & Kevin 
<image1.JPG>
Sent from my iPhone

On Apr 22, 2017, at 8:58 AM, Ken Young <kanawha72@xxxxxxxxxxx 
<mailto:kanawha72@xxxxxxxxxxx>> wrote:

I came up with a few problems/things to be considered with this design:
I only left 5" for the between modules jumper track at the first switches 
off the inner main. There needs to be another 5.5" straight before the 
switch so the jumper track doesn't connect directly to the more fragile 
switch.  Adding that 5.5" straight to both ends of the longer modules will 
shorten the yard about a foot. This may also have to make the outer modules 
7' long with the inner module at 4' so the furthest to the rear switches 
don't land on the module joints.
There are 12 switches = $.
I don't know what the ideas are for the raised station/city, but it 
shouldn't cover any switches or we will not be able to see to do switching.
Probably will need remote uncouplers on all the sidings = more $.
Lots of wiring. Will need some kind of control panel for switch controls, 
uncoupler buttons, and siding on/off switches. Also = more $.
Ken





On 4/22/2017 7:32 AM, Bill Michie wrote:
Good morning!  Based on all of the diagrams I've seen thus far (and I like 
all of them), I think Ken's second variation may be the one to consider, 
contingent on cost.
 
I wonder if we'll need to recruit a stationmaster…
 
Bill M.
 
From: rc3r-bounce@xxxxxxxxxxxxx <mailto:rc3r-bounce@xxxxxxxxxxxxx
[mailto:rc3r-bounce@xxxxxxxxxxxxx ;<mailto:rc3r-bounce@xxxxxxxxxxxxx>] On 
Behalf Of Ken Young
Sent: Friday, April 21, 2017 5:50 PM
To: rc3r@xxxxxxxxxxxxx <mailto:rc3r@xxxxxxxxxxxxx>
Subject: [rc3r] Re: Train Station Modules
 
I'm just throwing some ideas out here, but here's another variation on a 
pull through yard under the station. Still 18' of modules but reduced the 
width to 36". In order for the switches not to land on the module joints 
the outer modules are 6'-6 and the center module is 5'. Reading from bottom 
to top:
Tracks 1 & 2 are the mains
Track 3 has about 11' of storage (6- 21" scale length cars)
Track 4 has about 9' of storage (Maybe 5-21" scale length cars)
Track 5 has about 7' of storage ( 3 1/2 - 21" scale length cars)
Track 6 is a runaround track. I figure to get the most cars under the 
station you would pull in, decouple the engine, back it up to the runaround 
track and park it in one of the stub end sidings. When you want to pull the 
train out you simply take the engine out and couple back up to the train. 
You could also use the stub tracks for express or RPO cars.
Of course you can get more 15" or 18" cars into the yard. I was just 
looking at worst case. Again I'm using Atlas switches. I think Ross 
switches will cut down the distance between tracks about 1/2".

 

Ken


Other related posts: