[racktables-users] Re: Add cable ID to external cables

  • From: Marijn van Gool <marijn.vangool@xxxxxxxxxxx>
  • To: Ramon van der Wel <realpluut@xxxxxxxxx>
  • Date: Fri, 28 Feb 2020 13:07:06 +0100

Hi Ramon,

Thanks, that actually makes sense.
I see that racktables is very customizable, more than I thought :-)

Per dc I create a virtual rack, and I have created a object type 
interconnect. And I added fields to put contract name phone number and more.

I created a 1U rack in the demo environment and added a new object type called 
“Interconnect” and put it in the 1U rack.
Where do you create those new fields?

For every line to my dmarc I back link. To the interconnect object

Alright, so it’s just 1 Interconnect object you link everything to.

Marijn

On 28 Feb 2020, at 09:35, Ramon van der Wel <realpluut@xxxxxxxxx> wrote:

Hi,

The way I do it 
Per dc I create a virtual rack, and I have created a object type 
interconnect. And I added fields to put contract name phone number and more.

For that object I create 1 port with the id

For every line to my dmarc I back link. To the interconnect object

This way I have a full a to z path.

Ramon

On Fri, Feb 28, 2020, 09:05 Marijn van Gool <marijn.vangool@xxxxxxxxxxx 
<mailto:marijn.vangool@xxxxxxxxxxx>> wrote:
Hello,

I noticed that you can only add a cable ID (or circuit ID?) to a link when 
you link two devices and their interfaces together.
Now, in a datacenter, it’s common to have many external cables from 3rd 
parties coming in to your rack.
These cables or patches usually have some sort of a ID that identifies them 
and separates them from other cables.
This ID is known by both us and the external third party.

Is there a way to attach a cable / circuit ID to an interface?

Marijn

Other related posts: