Re: Shell Script to Supress OEM alerts during shutdown immediate

  • From: "Kellyn Pot'Vin-Gorman" <dbakevlar@xxxxxxxxx>
  • To: Arun Chugh <arun.chugh1610@xxxxxxxxx>
  • Date: Sat, 26 Mar 2016 14:19:01 -0600

Are you already using groups and monitoring templates?  You can easily do
this then by assigning incident rules and metric alerts to specific groups
that have the correct template monitoring for that metric extension.
Please use the features that are built into the EM12c environment to
support this and simplify your environment management.
Thank you,
Kellyn



[image: Kellyn Pot'Vin on about.me]

Kellyn Pot'Vin-Gorman
about.me/dbakevlar
  <http://about.me/dbakevlar>

On Sat, Mar 26, 2016 at 1:35 PM, Arun Chugh <arun.chugh1610@xxxxxxxxx>
wrote:

We want to supress the alert for lower env like SIT/DEV etc.. Not for
prod. If anyone has some idea for the same or handy scripts / procedure,
please share.

Regards,
Arun Chugh

Sent from my iPhone

On 26-Mar-2016, at 10:35 PM, Kellyn Pot'Vin-Gorman <dbakevlar@xxxxxxxxx>
wrote:

Thank you for letting me know.  Also be aware, by suppressing alerts that
are generated for outages, if you're not careful, you could set yourself up
for a real situation being disregarded as a planned outage by the EM.  I
would recommend investigating corrective actions that could be applied to a
carefully planned metric extension to monitor for this type of situation.

Hope this helps,
Kellyn



[image: Kellyn Pot'Vin on about.me]

Kellyn Pot'Vin-Gorman
about.me/dbakevlar
  <http://about.me/dbakevlar>

On Sat, Mar 26, 2016 at 9:25 AM, Arun Chugh <arun.chugh1610@xxxxxxxxx>
wrote:

Acutally the motive behind this is to reduce the number of incidents we
are getting due to database went down (intentionally) due to any DBA
activity, so we want the automatic supress of alerts.

No there is no such plan for upgrade in near future.

Sent from my iPhone

On 26-Mar-2016, at 8:27 PM, Kellyn Pot'Vin-Gorman <dbakevlar@xxxxxxxxx>
wrote:

I'm going to make a few assumptions here, so please let me know if this
is correct-

1.  You begin maintenance and submit the blackout.
2.  A flurry of alert notifications are sent and alarm the DBA on call
3.  You are looking for a way to avoid these.

The reason behind this situation is that the blackout signal to the agent
is controlled by the OMS in any verion 12.*.  With the introduction of
EM13c, the AGENT now controls the blackout, the communication to the OMS
and then the agent availability.  This change is valuable to correcting
this notification issue that [I believe] you're describing.

Let me know, as I can tell you, EM13c will solve this if you're already
planning on upgrading in the near future.

Kellyn Pot'Vin-Gorman
Consulting Member of Technical Team, SCP
Oracle Enterprise Manager and Oracle Management Cloud



[image: Kellyn Pot'Vin on about.me]

Kellyn Pot'Vin-Gorman
about.me/dbakevlar
  <http://about.me/dbakevlar>

On Sat, Mar 26, 2016 at 7:35 AM, Arun Chugh <arun.chugh1610@xxxxxxxxx>
wrote:

Thanks for the suggestion.

It would be great if anyone of you is having the procedure handy for
this task.

But one thing I want to mentioned here is that the database is running
thru oracle user and emagent is running thru grid user, so we need to setup
passwordless connection(ssh) for every server in order to run emcli command
via procedure and it would be very tedious task for entire setup or correct
me if I am wrong.

Regards,
Arun Chugh

Regards,
Arun Chugh

Sent from my iPhone

On 26-Mar-2016, at 5:59 PM, Niall Litchfield <niall.litchfield@xxxxxxxxx>
wrote:

You should

a) have procedures and script(s) for shutting down databases that
everyone follows
b) include the necessary emcli commands in the scripts

If someone doesn't follow procedure then I'd say that an alert and an
on-call page is exactly what you want to happen.


On Sat, Mar 26, 2016 at 10:54 AM, Arun Chugh <arun.chugh1610@xxxxxxxxx>
wrote:

Hi,

Thanks for the response.

Yes, this could be one of the solution but what happens, we forget to
put the blackout in OEM and start getting the alerts for the same, so we
want the automatic solution of it, if any DBA put down the DB with
"shutdown immediate" we should not receive any alerts.

Regards,
Arun Chugh

Sent from my iPhone

On 26-Mar-2016, at 4:05 PM, Ls Cheng <exriscer@xxxxxxxxx> wrote:

Hi

You mean Blackout? You can run emcli, this is an example

emcli create_blackout \
-name="MAINTENANCE" \
-add_targets="XXXX:oracle_database;ZZZZ:oracle_listener" \
-reason="MAINTENANCE WINDOW" \
-schedule="frequency:once;duration:0:30"

It blackouts 2 targets, one database and one listener for 30 minutes

Regards




On Sat, Mar 26, 2016 at 11:25 AM, Arun Chugh <arun.chugh1610@xxxxxxxxx>
wrote:

Hello Team,

Our requirement is to automatically supress the OEM alerts whenever
the database undergoes "shutdown immediate" during the refresh or
maintenance windows.

If someone have any script, please share. Thanks !!!

Regards,
Arun Chugh

Sent from my iPhone--
//www.freelists.org/webpage/oracle-l






--
Niall Litchfield
Oracle DBA
http://www.orawin.info




Other related posts: