Configuration setup (XP1024) =3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D= =3D=3D Hardware RAID (1+0) on 4 underlying Disks. 4 Units of 14 GB each are created using a Software emulation (OPEN-E, OPEN-9) on this underlying Hardware RAID (Each Unit is known as Logical Device [LDEV]) Each LDEV is assigned to a different Controller port. Volume Group [VG] created EITHER from a SINLE LDEV OR by O.S. Software Striping (RAID 0) across 4 LDEVs. Qs. For Redo Logs placing, which of the following 2 options is better? 1) Redo logs if placed on a Single LDEV-VG will have only a single level of Hardware RAID 1+0 & be assigned to a SINLE Controller port.=20 2) Redo logs if placed on a 4 LDEV's-VG will have 2 levels Striping (Both s/w & H/w) But also be assigned to 4 Controller ports. NOTE - Ideally Redo logfiles should exist on RAW or NON-Striped, Mirror Volume. Shall provide any details required Thanks ---------------------------------------------------------------- Please see the official ORACLE-L FAQ: http://www.orafaq.com ---------------------------------------------------------------- To unsubscribe send email to: oracle-l-request@xxxxxxxxxxxxx put 'unsubscribe' in the subject line. -- Archives are at //www.freelists.org/archives/oracle-l/ FAQ is at //www.freelists.org/help/fom-serve/cache/1.html -----------------------------------------------------------------