Re: Physical Standby Switchover issue

  • From: Sami Seerangan <dba.orcl@xxxxxxxxx>
  • To: Carel-Jan Engel <cjpengel.dbalert@xxxxxxxxx>
  • Date: Mon, 5 Sep 2005 09:49:18 -0400

Carel,

I am running only one instance on both Primary and Standby side. Anything 
else yiu can think of?

Thanks for your response.

Sami


On 9/5/05, Carel-Jan Engel <cjpengel.dbalert@xxxxxxxxx> wrote:
> 
> Sami
> 
> I guess this is still the RAC HA sandbox system you're using for your POC?
> 
> Did you shutdown all but one instance at both ends? During switchover only 
> one instance per database is allowed to run.
>   
>

Other related posts: