I’m not aware of being able to hot clone a PDB from a physical standby. In
order to do it, you have to convert it to a snapshot standby, which does
require redo apply to stop, but now redo transport.
---
Thanks,
Shane Borden
sborden76@xxxxxxxxx
407-963-4883
On Sep 3, 2020, at 12:20 AM, Jack van Zanen <jack@xxxxxxxxxxxx> wrote:
Hi
We are on 12.2 with local undo so hot cloning is supported.
We clone from our data guard standby though and so far we always turn off the
redo apply before we clone from DR.
Do we really need to turn off the redo apply ?
I can not find any documents about hot cloning from DR
Regards
Jack van Zanen
-------------------------
This e-mail and any attachments may contain confidential material for the
sole use of the intended recipient. If you are not the intended recipient,
please be aware that any disclosure, copying, distribution or use of this
e-mail or any attachment is prohibited. If you have received this e-mail in
error, please contact the sender and delete all copies.
Thank you for your cooperation