Re: Does ASM's EXTERNAL REDUNDANCY concatenate?

  • From: Manuela Atoui <atoui@xxxxxxxxxxxxx>
  • Date: Mon, 30 Jun 2008 16:38:18 +0200

Hello Martin,
I saw there's a patch available, at least for 10.2.0.2:
http://updates.oracle.com/ARULink/PatchDetails/process_form?patch_num=6453944

Regards
Manuela

Martin Klier wrote:

Hi Jason,

thanks for the reply.

jason arneil schrieb:
the diskgroup, ASM will stripe your data across the devices.
Okay, I guessed so, but I wasn't sure. Thanks.

You can easily get around the issue that you mention by adding multiple
devices to the diskgroup that are below the 2TB threshold. I don't see
this as being too much of a problem?
Normally not. But unfortunately, I am on dedicated storage with a
superfast Adaptec 5085 RAID controller. It has a disadvantage: When
using RAID 6 (which is very fast on this hardware) it has only enough
segments for 4 logical drives. And 4 times 2 TB are too less :(

Regards
Martin Klier

begin:vcard
fn:Manuela Atoui
n:Atoui;Manuela
org:FIZ CHEMIE Berlin;PI
adr;dom:;;Franklinstr. 11;Berlin;;10587
email;internet:atoui@xxxxxxxxxxxxx
title:Software Entwickler, Oracle DBA
tel;work:+49 30 399 77-206
note;quoted-printable:Geschaeftsfuehrer: Prof. Dr. R. Deplanque=0D=0A=
        Aufsichtsratsvorsitzender: SenRat Bernd Lietzau, Berlin=0D=0A=
        Registergericht: Amtsgericht Charlottenburg HRB 19047=0D=0A=
        USt.-ID Nr.: DE 136 629 878=0D=0A=
        =0D=0A=
        FIZ CHEMIE Berlin ist ein Institut der Leibniz Gemeinschaft=0D=0A=
        
url:htttp://www.fiz-chemie.de
version:2.1
end:vcard

Other related posts: