Thank you Mark, Ron! Best Regards, Mike Tsinberg http://keydigital.com<http://keydigital.com/> From: opendtv-bounce@xxxxxxxxxxxxx [mailto:opendtv-bounce@xxxxxxxxxxxxx] On Behalf Of Ron Economos Sent: Monday, December 08, 2014 2:23 PM To: opendtv@xxxxxxxxxxxxx Subject: [opendtv] Re: HD-SDI connecting length Belden rates the maximum length for HD-SDI and 3G-SDI to be 20 dB loss at 1/2 the clock frequency. The very best cable seems to be 7731A (RG-11/U 0.4 inch diameter), which is good for 580 feet with HD-SDI and 393 feet with 3G-SDI. http://www.belden.com/resourcecenter/tools/upload/TB65_p28.pdf Ron On 12/08/2014 10:44 AM, Mike Tsinberg wrote: Thanks Mark, What is the state of the art today? Best Regards, Mike Tsinberg http://keydigital.com<http://keydigital.com/> From: opendtv-bounce@xxxxxxxxxxxxx<mailto:opendtv-bounce@xxxxxxxxxxxxx> [mailto:opendtv-bounce@xxxxxxxxxxxxx] On Behalf Of Mark Schubin Sent: Monday, December 08, 2014 1:44 PM To: opendtv@xxxxxxxxxxxxx<mailto:opendtv@xxxxxxxxxxxxx> Subject: [opendtv] Re: HD-SDI connecting length It depends on the cable -- but expect "A MAJOR ANNOUNCEMENT" from Belden at the HPA Tech Retreat in February. TTFN, Mark On 12/8/2014 1:10 PM, Mike Tsinberg wrote: What is practical length that HD-SDI can connect for 1080p/12bit/4:2:2/60, 4K/10bit/4:2:2/24 and 4K/8bit/4:2:0/60? Best Regards, Mike Tsinberg http://keydigital.com<http://keydigital.com/>