[ibis] Re: [ibis-users] IBIS model for CPHY MIPI standard

  • From: Mike LaBonte <mlabonte@xxxxxxxxxx>
  • To: <aessam@xxxxxxxxx>, <ibis-users@xxxxxxxxxxxxx>, <ibis@xxxxxxxxxxxxx>
  • Date: Mon, 31 Oct 2016 08:26:13 -0400 (EDT)

The MIPI C-PHY 3-wire protocol does introduce a new concept, and this seems 
like a useful discussion for the Advanced Technology Modeling group. Anyone 
interested in discussing any new IBIS topic can join the ibis-macro list 
(now the Advanced Technology Modeling list) at 
//www.freelists.org/list/ibis-macro



Mike



From: ibis-users-bounce@xxxxxxxxxxxxx 
[mailto:ibis-users-bounce@xxxxxxxxxxxxx] On Behalf Of Ahmed Essam
Sent: Sunday, October 30, 2016 3:57 PM
To: ibis-users@xxxxxxxxxxxxx; ibis@xxxxxxxxxxxxx
Subject: [ibis-users] IBIS model for CPHY MIPI standard



Dear ALL,



I have faced a problem while creating IBIS model for CPHY MIPI standard.The 
standard has 3 states on the transmission line (High,Low,Midlevel) .



The transmission line is driven to high state through pull up device,driven 
to low state through pull down device,driven to mid level state through both 
pull up & pull down devices.



I wonder if IBIS standard can model CPHY standard "driving the transmission 
line to 3 states" .



Thanks,

Ahmed

Other related posts: