Hi Manish,
Here is one reference where IBIS clamp data is extended by VHDL-AMS to model
"snap back" effects that might be associated with large voltage spikes.
https://hal.archives-ouvertes.fr/hal-00941823/document
There are other references in this document. I do not know if this
addresses your question.
Best Regards,
Bob
From: ibis-users-bounce@xxxxxxxxxxxxx
[mailto:ibis-users-bounce@xxxxxxxxxxxxx] On Behalf Of Manish-FTM Bansal
(Redacted sender "manish.bansal" for DMARC)
Sent: Wednesday, December 9, 2020 10:25 PM
To: 'ibis@xxxxxxxxxxxxx'; ibis-users@xxxxxxxxxxxxx
Subject: [ibis-users] IBIS Usage for ESD Simulations
Hello Experts,
Can IBIS models be used for ESD simulations.
If yes, how can we add the ESD I-V Data (uptp 2kV) in the IBIS models.
Thanks & Regards,
Manish Bansal