Mike, Since when can param and value be interpreted as an array of string? According to the spec a string begins and ends with a double quote ("), so the only way I see those two words being a string array is if you did "param" "value". Am I missing something? | ASCII string following Description describes a reserved parameter, | model specific parameter, or the Algorithmic model itself. It is used | by the EDA platform to convey information to the end-user. The entire | line has to be limited to IBIS line length specification. String | literals begin and end with a double quote (") and no double quotes are | allowed inside the string literals. Arpad ====================================================================== -----Original Message----- From: ibis-macro-bounce@xxxxxxxxxxxxx [mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Mike Steinberger Sent: Wednesday, March 17, 2010 8:36 AM To: fangyi_rao@xxxxxxxxxxx Cc: ibis-macro@xxxxxxxxxxxxx Subject: [ibis-macro] Re: question about string parameter in AMI Fangyi- It looks like this one's been sitting out there for a day or so, so I'll offer an answer. The answer depends partially on whether or not "param_value" contains white space. If it does not, then either form should work equally well in the parameter string, and the parser in the model should support either form without complaint since both forms are fully compliant with the published syntax. The parser we published in 2007 does, so I don't see any excuse for failing to provide this functionality. If "param_value" is actually "param value", then (param_name "param value") will work, but (param_name param value) will be mistakenly interpreted as an array of strings. Mike S. fangyi_rao@xxxxxxxxxxx wrote: > > Hi, Experts; > > Shall the double quote of the value of a string parameter be included > in the input parameter string of the Init call? For example, if an AMI > model has a string parameter with name "param_name" and value > "param_value", should the input parameter string be > > (param_name "param_value") > > or > > (param_name param_value) > > Thanks in advance, > > Fangyi > --------------------------------------------------------------------- IBIS Macro website : http://www.eda.org/pub/ibis/macromodel_wip/ IBIS Macro reflector: //www.freelists.org/list/ibis-macro To unsubscribe send an email: To: ibis-macro-request@xxxxxxxxxxxxx Subject: unsubscribe --------------------------------------------------------------------- IBIS Macro website : http://www.eda.org/pub/ibis/macromodel_wip/ IBIS Macro reflector: //www.freelists.org/list/ibis-macro To unsubscribe send an email: To: ibis-macro-request@xxxxxxxxxxxxx Subject: unsubscribe