Hi Tom,

Thanks for the reply!

So, in this case, is the goal to assess, in simulation, the difference between 
the absolute potentials of two areas of the circuit, which are physically 
disparate?

-db


On Mar 7, 2018, at 1:08 PM, Tom Dagostino <tom@xxxxxxxxxxxxxxxxx> wrote:

Anywhere you have long coax or twinax?
 
Tom Dagostino
    
971-279-5325
tom@xxxxxxxxxxxxxxxxx <mailto:tom@xxxxxxxxxxxxxxxxx>
 
<image001.png>
 
From: ibis-macro-bounce@xxxxxxxxxxxxx 
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of David Banas
Sent: Wednesday, March 07, 2018 11:57 AM
To: bradb@xxxxxxxxxxx
Cc: Walter Katz; ibis-macro@xxxxxxxxxxxxx; ibis-interconn@xxxxxxxxxxxxx
Subject: [ibis-macro] Re: [ibis-interconn] Re: A_gnd in IBIS 6.1
 
For some subcircuits there will be a desire to have only a local reference 
for voltage.
 
Could someone, please, provide an example of the above?
 
Thanks,
-db


On Mar 7, 2018, at 10:42 AM, Bradley Brim <bradb@xxxxxxxxxxx 
<mailto:bradb@xxxxxxxxxxx>> wrote:
 
For some subcircuits there will be a desire to have only a local reference 
for voltage.

Other related posts: