[ibis-macro] Re: [ibis-interconn] Re: A_gnd in IBIS 6.1

  • From: Bradley Brim <bradb@xxxxxxxxxxx>
  • To: "wkatz@xxxxxxxxxx" <wkatz@xxxxxxxxxx>, IBIS-ATM <ibis-macro@xxxxxxxxxxxxx>, "ibis-interconn@xxxxxxxxxxxxx" <ibis-interconn@xxxxxxxxxxxxx>
  • Date: Wed, 7 Mar 2018 18:42:35 +0000

Hello all,

Life would be a LOT more simple if we all quit using the word "ground". The 
biggest service we could do for the industry is to remove the word "ground" and 
anything qualified by "gnd" from the IBIS documents.

There is a single node named "0". For most (but not all)  circuit simulators 
this is a global node. For these simulators, this node is applied as the 
default reference for voltage. This node would much more appropriately be named 
"GlobalRef" but "0" is easier. For some subcircuits there will be a desire to 
have only a local reference for voltage. If this local reference were named 
"LocalRef" there would be no confusion. The only thing to worry about is 
whether "LocalRef" is connected directly to "GlobalRef".

It is really that simple,
-Brad

P.S.  .  A few circuit simulators (by definition or by option) and all 
non-static EM simulators do not have global nodes, therefore they have no 
"GlobalRef".


From: ibis-interconn-bounce@xxxxxxxxxxxxx 
[mailto:ibis-interconn-bounce@xxxxxxxxxxxxx] On Behalf Of Walter Katz
Sent: Wednesday, March 7, 2018 8:39 AM
To: IBIS-ATM <ibis-macro@xxxxxxxxxxxxx>; ibis-interconn@xxxxxxxxxxxxx
Subject: [ibis-interconn] Re: A_gnd in IBIS 6.1

EXTERNAL MAIL
Arpad,

This is perfect, I did not remember we changed this:

A_gnd is a reference node of the [Component]. It represents a "local" ground, 
and the EDA tool may connect it to the global ground (similar to SPICE ideal 
node "0"). The local ground is the reference node for the I/O signal(s).

I think it may be useful to define "local" ground as "signal ground" as defined 
in the literature.

Walter

Walter Katz
wkatz@xxxxxxxxxx<mailto:wkatz@xxxxxxxxxx>
978.461-0449 x 133
Mobile 303.335-6156

From: 
ibis-interconn-bounce@xxxxxxxxxxxxx<mailto:ibis-interconn-bounce@xxxxxxxxxxxxx
[mailto:ibis-interconn-bounce@xxxxxxxxxxxxx] On Behalf Of Muranyi, Arpad
Sent: Wednesday, March 7, 2018 10:39 AM
To: IBIS-ATM <ibis-macro@xxxxxxxxxxxxx<mailto:ibis-macro@xxxxxxxxxxxxx>>; 
ibis-interconn@xxxxxxxxxxxxx<mailto:ibis-interconn@xxxxxxxxxxxxx>
Subject: [ibis-interconn] Re: A_gnd in IBIS 6.1

Walter,

Starting with bird189.5_draft18_v1, we have this:


In Page 94 replace:



A_gnd is a universal reference node, similar to SPICE ideal node "0."



with



A_gnd is a reference node of the [Component]. It represents a "local" ground, 
and the EDA tool may connect it to the global ground (similar to SPICE ideal 
node "0"). The local ground is the reference node for the I/O signal(s).


Let's agree on what A_gnd is first...

Thanks,

Arpad
================================

From: 
ibis-interconn-bounce@xxxxxxxxxxxxx<mailto:ibis-interconn-bounce@xxxxxxxxxxxxx
[mailto:ibis-interconn-bounce@xxxxxxxxxxxxx] On Behalf Of Walter Katz
Sent: Wednesday, March 7, 2018 7:55 AM
To: IBIS-ATM <ibis-macro@xxxxxxxxxxxxx<mailto:ibis-macro@xxxxxxxxxxxxx>>; 
ibis-interconn@xxxxxxxxxxxxx<mailto:ibis-interconn@xxxxxxxxxxxxx>
Subject: [ibis-interconn] A_gnd in IBIS 6.1

All,

In IBIS 6.1

On Page 94


11


A_gnd


Global reference voltage port


...







A_gnd is a universal reference node, similar to SPICE ideal node "0."


Page 123
One of these port entries must name a reference for the other port (for 
example, A_gnd).

The line on Page 123 is consistent with the usage we are including in BIRDs 158 
and 189. I suggest the following changes:


11


A_gnd


Local reference voltage port


...







A_gnd is a signal ground or reference node for measuring voltages. A_gnd can be 
either a universal reference node, similar to SPICE ideal node "0", or a node 
near the node being measured.

Other than BIRDs 158 and 189, A_gnd does not appear in any other BIRDs that 
have been approved for IBIS 7.0

Walter

Walter Katz
wkatz@xxxxxxxxxx<mailto:wkatz@xxxxxxxxxx>
978.461-0449 x 133
Mobile 303.335-6156

Other related posts: