[ibis-macro] Re: [ibis-interconn] Re: A_gnd in IBIS 6.1

  • From: Walter Katz <wkatz@xxxxxxxxxx>
  • To: "IBIS-ATM" <ibis-macro@xxxxxxxxxxxxx>, <ibis-interconn@xxxxxxxxxxxxx>
  • Date: Wed, 7 Mar 2018 11:38:47 -0500 (EST)

Arpad,

 

This is perfect, I did not remember we changed this:

A_gnd is a reference node of the [Component]. It represents a "local"
ground, and the EDA tool may connect it to the global ground (similar to
SPICE ideal node "0"). The local ground is the reference node for the I/O
signal(s). 

 

I think it may be useful to define "local" ground as "signal ground" as
defined in the literature.

 

Walter

 

Walter Katz

 <mailto:wkatz@xxxxxxxxxx> wkatz@xxxxxxxxxx

978.461-0449 x 133

Mobile 303.335-6156

 

From: ibis-interconn-bounce@xxxxxxxxxxxxx
[mailto:ibis-interconn-bounce@xxxxxxxxxxxxx] On Behalf Of Muranyi, Arpad
Sent: Wednesday, March 7, 2018 10:39 AM
To: IBIS-ATM <ibis-macro@xxxxxxxxxxxxx>; ibis-interconn@xxxxxxxxxxxxx
Subject: [ibis-interconn] Re: A_gnd in IBIS 6.1

 

Walter,

 

Starting with bird189.5_draft18_v1, we have this:

 

In Page 94 replace:
 
A_gnd is a universal reference node, similar to SPICE ideal node "0."  
 
with
 
A_gnd is a reference node of the [Component]. It represents a "local"
ground, and the EDA tool may connect it to the global ground (similar to
SPICE ideal node "0"). The local ground is the reference node for the I/O
signal(s). 

 

 

Let's agree on what A_gnd is first.

 

Thanks,

 

Arpad

================================

 

From: ibis-interconn-bounce@xxxxxxxxxxxxx
<mailto:ibis-interconn-bounce@xxxxxxxxxxxxx>
[mailto:ibis-interconn-bounce@xxxxxxxxxxxxx] On Behalf Of Walter Katz
Sent: Wednesday, March 7, 2018 7:55 AM
To: IBIS-ATM <ibis-macro@xxxxxxxxxxxxx>; ibis-interconn@xxxxxxxxxxxxx
<mailto:ibis-interconn@xxxxxxxxxxxxx
Subject: [ibis-interconn] A_gnd in IBIS 6.1

 

All,

 

In IBIS 6.1

 

On Page 94

 


11 

A_gnd 

Global reference voltage port 


.

 

 

A_gnd is a universal reference node, similar to SPICE ideal node "0."

 

 

Page 123

One of these port entries must name a reference for the other port (for
example, A_gnd).

 

The line on Page 123 is consistent with the usage we are including in
BIRDs 158 and 189. I suggest the following changes:

 


11 

A_gnd 

Local reference voltage port 


.

 

 

A_gnd is a signal ground or reference node for measuring voltages. A_gnd
can be either a universal reference node, similar to SPICE ideal node "0",
or a node near the node being measured.

 

Other than BIRDs 158 and 189, A_gnd does not appear in any other BIRDs
that have been approved for IBIS 7.0

 

Walter

 

Walter Katz

 <mailto:wkatz@xxxxxxxxxx> wkatz@xxxxxxxxxx

978.461-0449 x 133

Mobile 303.335-6156

 

Other related posts: