[ibis-macro] Re: Table Clarification BIRD Comments

  • From: "Walter Katz" <wkatz@xxxxxxxxxx>
  • To: <bob@xxxxxxxxxxxxx>, "'IBIS-ATM'" <ibis-macro@xxxxxxxxxxxxx>
  • Date: Tue, 29 Mar 2011 21:46:29 -0400 (EDT)

All,

I have reviewed Bob's comments, and am enclosing a response with my
comments. I am in agreement with all of Bob's comments, except the
treatment of the first column in each row. With my proposal, the format of
single row tables and multi row tables are the same, and by treating the
first column of each row as a "parameter", then is satisfies all of the
DLL BNF rules.

The alternative is to treat single row tables differently than multi row
tables.  I will accept the decision the IBIS-ATM, my real goal here is to
not need to have context sensitive parsers in either the EDA tool, or
models.

Walter
 
-----Original Message-----
From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Bob Ross
Sent: Tuesday, March 29, 2011 2:15 PM
To: 'IBIS-ATM'
Subject: [ibis-macro] Table Clarification BIRD Comments

All:

Per Arpad's request, attached are my comments on top and in the BIRD.

Bob

--
Bob Ross
Teraspeed Consulting Group, LCC
http://www.teraspeed.com
bob@xxxxxxxxxxxxxx
Direct : 503-246-8048
Teraspeed Labs: 503-430-1065
Headquarters: 401-284-1827

Teraspeed is a registered service mark of Teraspeed Consulting Group LLC

Other related posts: