[ibis-macro] Simple IBIS-AMI question of the day...

  • From: "Mirmak, Michael" <michael.mirmak@xxxxxxxxx>
  • To: "IBIS-ATM (ibis-macro@xxxxxxxxxxxxx)" <ibis-macro@xxxxxxxxxxxxx>
  • Date: Fri, 25 Mar 2016 20:10:40 +0000

I note that jitter parameters such as Rx_Dj are described in the IBIS document 
as having Usage Info, Out, and Dep.



Ignoring Dep for the moment...



The specification defines Info as referring to parameters that may be of 
interest to the EDA tool or to the user.  Out is defined as referring to 
parameters "coming from the AMI_Init and/or AMI_GetWave functions."



If the Usage is Info for a jitter reserved parameter, then I would assume the 
jitter values will be read by the EDA tool to ensure it takes jitter into 
account properly.



But what about Usage Out?  This implies that the functions AMI_Init and/or 
AMI_GetWave are generating the jitter.  In this case, is Usage Out for jitter 
meant to help a model-maker include the jitter in the DLL (and conceal it from 
readers of the .ami file) but still make it available to the tool?



Thanks in advance...



-          MM