[ibis-macro] Re: Let me clarify the benifit of getting rid of Use_Init_Output along with Digital Input to Tx GetWave

  • From: "Walter Katz" <wkatz@xxxxxxxxxx>
  • To: <fangyi_rao@xxxxxxxxxxx>, <ibis-macro@xxxxxxxxxxxxx>
  • Date: Thu, 8 Oct 2009 17:33:50 -0400

Fangyi,

Arpad is exactly right. I defined the digital waveform as.

|  Step 4. The simulation platform produces a digital stimulus waveform.
|          A digital stimulus waveform is .5 when the stimulus is "high",
|          -.5 when the stimulus is "low", and may have a value between
|          -.5 and .5 such transitions occur when the stimulus crosses 0.

Walter

Walter Katz
303.449-2308
Mobile 720.333-1107
wkatz@xxxxxxxxxx
www.sisoft.com

-----Original Message-----
From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx]On Behalf Of Muranyi, Arpad
Sent: Thursday, October 08, 2009 5:23 PM
To: ibis-macro@xxxxxxxxxxxxx
Subject: [ibis-macro] Re: Let me clarify the benifit of getting rid of
Use_Init_Output along with Digital Input to Tx GetWave

Yes, that's how you can position the exact location
for the zero crossing to add jitter or DCD in finer
resolution than the sampling time.

Arpad
=====================================================

  _____

From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of fangyi_rao@xxxxxxxxxxx
Sent: Thursday, October 08, 2009 4:04 PM
To: wkatz@xxxxxxxxxx; ibis-macro@xxxxxxxxxxxxx
Subject: [ibis-macro] Re: Let me clarify the benifit of getting rid of
Use_Init_Output along with Digital Input to Tx GetWave
Hi, Walter;

I understand that the digital input swings between -0.5 and 0.5. Is the
waveform allowed to have values between -0.5 and 0.5 during transition?

Thanks,
Fangyi

From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Walter Katz
Sent: Tuesday, October 06, 2009 1:48 PM
To: Ambrish Varma; IBIS-ATM
Subject: [ibis-macro] Let me clarify the benifit of getting rid of
Use_Init_Output along with Digital Input to Tx GetWave

Ambrish,

We have proven that the "Digital Input" to Tx GetWave is required.

The whole concept of Use_Init_Output was introduced because Kumar and
Cadence rejected requiring the model to implement the convolution of the
impulse response of the Rx linear filter in the Rx GetWave. Kumar repeated
his objection to doing this convolution in a recent IBIS-ATM meeting.

If Use_Init_Output is True then the flow of using an externally generated
waveform (e.g. Spice simulation) as input to the Rx GetWave is broken. It
breaks the flow because the EDA tool is required to convolve the output of
the Rx Init with the input to Rx GetWave. The input to Rx GetWave already
contains the loss of the channel, so does the output of Rx Init.

The argument that model writers are not capable to do this simple
convolution is condescending to say the least.

I would expect anyone who is capable of writing a model is capable of
implement the code described in

  http://en.wikipedia.org/wiki/Overlap-save_method

   (Overlap-save algorithm for linear convolution)
   H = FFT(h,N)
   i = 1
   while i <= Nx
       il = min(i+N-1,Nx)
       yt = IFFT( FFT(x(i:il),N) * H, N)
       y(i : i+N-M) = yt(M : N)
       i = i+N-M+1
   end

So if we get rid of Use_Init_Output, we do not need Init_Returns_Filter
(although SiSoft will be generating models with this as a Model Specific
Parameter, even if it does not become a Reserved Parameter).

I have already spent many man months of effort on Analog Input to Tx
GetWave, and Use_Init_Output, and frankly I do not want to spend any more
time on it.

Walter

Walter Katz
303.449-2308
Mobile 720.333-1107
wkatz@xxxxxxxxxx
www.sisoft.com

Other related posts: