[ibis-macro] IBIS ATM task group minutes (May 22, 2018)

  • From: "Randy Wolff" <dmarc-noreply@xxxxxxxxxxxxx> (Redacted sender "rrwolff" for DMARC)
  • To: "ibis-macro@xxxxxxxxxxxxx" <ibis-macro@xxxxxxxxxxxxx>
  • Date: Wed, 23 May 2018 16:07:02 +0000

Minutes from the May 22 IBIS ATM task group meeting are attached.

Randy
IBIS Advanced Technology Modeling (ATM) Task Group

Meeting date: 22 May 2018

Members (asterisk for those attending):
ANSYS:                        Dan Dvorscak
                              Curtis Clark
Cadence Design Systems:       Ambrish Varma
                              Brad Brim
                              Kumar Keshavan
                              Ken Willis
eASIC:                        David Banas
GlobalFoundries:              Steve Parker
IBM                           Luis Armenta
                              Trevor Timpane
Intel:                        Michael Mirmak
Keysight Technologies:        Fangyi Rao
                            * Radek Biernacki
                              Ming Yan
Mentor, A Siemens Business:   John Angulo
                            * Arpad Muranyi
Micron Technology:          * Randy Wolff
                            * Justin Butterfield
SiSoft:                       Walter Katz
                              Todd Westerhoff
                              Mike LaBonte
SPISim:                     * Wei-hsing Huang
Synopsys:                     Rita Horner
                              Kevin Li
Teraspeed Consulting Group:   Scott McMorrow
Teraspeed Labs:             * Bob Ross
    
The meeting was led by Arpad Muranyi.  Randy Wolff took the minutes.

--------------------------------------------------------------------------------
Opens:

- Arpad discussed when to start working on the EMD proposal.  Randy mentioned 
that this would be best discussed in the Interconnect Task Group.

-------------
Review of ARs:

- None.

--------------------------
Call for patent disclosure:

- None.

-------------------------
Review of Meeting Minutes:

Arpad asked for any comments or corrections to the minutes of the May 15 
meeting.  Radek moved to approve the minutes.  Bob seconded the motion.  There 
were no objections.

-------------
New Discussion:

- Discussion: Allow Terminator as a Model_type for IBIS-AMI receivers

Arpad noted Curtis sent in email a comment that he preferred the first option 
for handling terminators that were in Michael's slides shown last week.  Bob 
mentioned that he'd like to see a BIRD proposal to discuss.  Radek noted he 
supported the same option as Curtis, the simplest option.  

Arpad wanted to look at whether the Terminator parameters could be split to 
the proper reference nodes.  The bottom end of the Terminator is connected to 
the ground symbol in the schematic.  This may cause complications with power 
aware simulations.  If this is strictly for AMI purposes, then it would 
probably be ok to have the Node 0 ground reference.  But, this could cause 
problems if people try to include power aware effects in the channel 
characterization for IBIS-AMI simulation.  Bob noted the existing Terminator 
fits with IBIS-AMI in the way people are simulating now.  Radek did not see a 
problem either, since option 1 is exclusively for AMI.  

Bob noted we are breaking a paradigm by including thresholds in a Terminator, 
but it works for AMI.  Terminator could be expanded further to support more 
complicated modeling for AMI.  

Arpad's thoughts on the 2nd or 3rd options in Michael's presentation is that 
one would need to split the Rac and Cac elements to go to the POWER Clamp 
Reference and GND Clamp Reference terminals.  This is seen in Figure 11 of the 
IBIS 6.1 specification.  The C_comp in that figure has alrady been dealt with 
for splitting to multiple references.  Arpad noted the proposal was made due 
to the simplicity of using existing model types for AMI.  BIRD158 modeling 
uses Node 0 references, so the Terminator is compatible with that.  Arpad was 
wondering if this could cause issues with including power delivery effects, 
with the Node 0 connection.  

Bob noted the RC construct is fixed in Terminator, so this limits the model's 
usefulness.  Arpad noted option 1 is the easiest solution as long as everyone 
agrees that the Node 0 in the Terminator model is not a problem.

- Discussion: BIRD194 (158) comments

Arpad asked if this topic should be kept on the active discussion list.  Radek 
thought we should keep it on the list.  Michael had some questions last week 
on lab correlation that could be discussed further.

--------------------------
Motion to Adjourn:
  
Randy moved to adjourn.  Radek seconded the motion.  Arpad thanked everyone 
for joining.

-------------
Next meeting: 29 May 2018 12:00pm PT
-------------