Hi Arpad,

I am as surprised by this interpretation as you are.

Actually, even for the reserved parameters I do not recall any requirement to 
convert a value specified in terms of UI to absolute seconds. In other words if 
the model creator designates a parameter as of type UI the model should expect 
the fraction of UI (time normalized w.r.t. the bit time) as its input.

Otherwise, why would we need Type UI at all?

Radek


-----Original Message-----
From: ibis-macro-bounce@xxxxxxxxxxxxx [mailto:ibis-macro-bounce@xxxxxxxxxxxxx] 
On Behalf Of Muranyi, Arpad
Sent: Wednesday, April 18, 2012 3:09 PM
To: IBIS-ATM
Subject: [ibis-macro] A technical question on UI

Hello everyone,

An interesting question was raised in the Editorial Committee meeting this 
morning, and I got the AR to write an email on this reflector to solicit for 
some comments and feedback.

The question is revolving around parameters which are expressed in terms of UI 
(unit interval).  A statement was made in the Editorial Committee meeting this 
morning, that if a parameter is a Reserved_Parameter, the tool will know what 
to do with it because all Reserved_Parameters are completely described in the 
specification.
However, if the parameter is a Model_Specific parameter, the EDA tool will have 
to convert the value from UI to time and pass the time value to the AMI 
executable model.

For example, if the bit time is 400e-12 (ps) and the UI value is
0.5 for a certain parameter, the EDA tool would have to pass
200e-12 to the DLL, and not 0.5.

(Please correct me if this summary is not accurate).

This surprised me, because I don't recall anything in the IBIS-AMI 
specification that states that the EDA tool has to convert parameters expressed 
in UI to time and pass the time value to the DLL.  If I were writing the 
simulation software, I would just pass 0.5 to the DLL.

Does anyone have any comments on how this is supposed to be handled by the EDA 
tool?

Once we have consensus on that question, the next question will be whether we 
can correct/clarify this as part of the Editorial Committee, or whether a BIRD 
is necessary to address this question.

Thanks in advance for the comments,

Arpad
======================================================================
---------------------------------------------------------------------
IBIS Macro website  :  http://www.eda.org/pub/ibis/macromodel_wip/
IBIS Macro reflector:  //www.freelists.org/list/ibis-macro
To unsubscribe send an email:
  To: ibis-macro-request@xxxxxxxxxxxxx
  Subject: unsubscribe

---------------------------------------------------------------------
IBIS Macro website  :  http://www.eda.org/pub/ibis/macromodel_wip/
IBIS Macro reflector:  //www.freelists.org/list/ibis-macro
To unsubscribe send an email:
  To: ibis-macro-request@xxxxxxxxxxxxx
  Subject: unsubscribe

Other related posts: