[ibis-macro] A_gnd in IBIS 6.1

  • From: Walter Katz <wkatz@xxxxxxxxxx>
  • To: "IBIS-ATM" <ibis-macro@xxxxxxxxxxxxx>, <ibis-interconn@xxxxxxxxxxxxx>
  • Date: Wed, 7 Mar 2018 08:54:43 -0500 (EST)

All,

 

In IBIS 6.1

 

On Page 94

 


11 

A_gnd 

Global reference voltage port 


.

 

 

A_gnd is a universal reference node, similar to SPICE ideal node "0."

 

 

Page 123

One of these port entries must name a reference for the other port (for
example, A_gnd).

 

The line on Page 123 is consistent with the usage we are including in
BIRDs 158 and 189. I suggest the following changes:

 


11 

A_gnd 

Local reference voltage port 


.

 

 

A_gnd is a signal ground or reference node for measuring voltages. A_gnd
can be either a universal reference node, similar to SPICE ideal node "0",
or a node near the node being measured.

 

Other than BIRDs 158 and 189, A_gnd does not appear in any other BIRDs
that have been approved for IBIS 7.0

 

Walter

 

Walter Katz

 <mailto:wkatz@xxxxxxxxxx> wkatz@xxxxxxxxxx

978.461-0449 x 133

Mobile 303.335-6156

 

Other related posts: