Bob,



Thanks for your comments!  I look forward to seeing the complete set.



All,



I strongly encourage everyone to review the rev. 0.140 draft and provide 
comments, either on this list or directly to me, as soon as possible.  In 
particular, I would request that the added technical information be checked 
very carefully for consistency with the original IBIS-AMI intent and industry 
understanding.



We will concentrate in this week's IBIS Editorial Task Group meeting on 
technical issues, particularly on the terminology used, units-related language 
and the new introductory text in Section 6C.



-          MM



From: ibis-editorial-bounce@xxxxxxxxxxxxx 
[mailto:ibis-editorial-bounce@xxxxxxxxxxxxx] On Behalf Of Bob Ross
Sent: Wednesday, May 02, 2012 4:35 AM
To: ibis-editorial@xxxxxxxxxxxxx
Subject: [ibis-editorial] Re: Revision 0.140 of draft reformatted IBIS 5.1



Michael:



Here are some partial review comments as a start,

but I have several more to consider.



Bob



From: 
ibis-editorial-bounce@xxxxxxxxxxxxx<mailto:ibis-editorial-bounce@xxxxxxxxxxxxx> 
[mailto:ibis-editorial-bounce@xxxxxxxxxxxxx]<mailto:[mailto:ibis-editorial-bounce@xxxxxxxxxxxxx]>
 On Behalf Of Mirmak, Michael
Sent: Thursday, April 26, 2012 12:00 AM
To: ibis-editorial@xxxxxxxxxxxxx<mailto:ibis-editorial@xxxxxxxxxxxxx>
Subject: [ibis-editorial] Revision 0.140 of draft reformatted IBIS 5.1



Per our discussions in today's meeting, please find rev. 0.140 of the draft 
reformatted IBIS 5.1 document (the Word document is being posted to the website)



Major changes include:

-          Examples now all use 0/0 paragraph spacing

-          All Table cross-references fixed

-          Introductory text on added to Section 6C

-          Bob's Section 10A, Rev. Z rules have been enforced

-          Model Specific Parameter restrictions have been removed

-          Bob's list of language variations were used to make terminology 
consistent

-          Jitter Reserved Parameters in Section 10A have "table" properly 
explained for units, per today's e-mail thread

-          Numerical values have been added to the examples



This does not yet include Walter's "node" changes; these will be integrated 
next.



Comments are welcome.



-          MM