[gpumd] Criteria for choosing F_e in HNEMD scheme.

  • From: "소순성" <soonsung2001@xxxxxxxxxx>
  • To: <gpumd@xxxxxxxxxxxxx>
  • Date: Fri, 11 Dec 2020 18:03:02 +0900

Hi, Fan
I'm Soonsung So and Thank you for your nice GPUMD package.

I have some questions today.

When I use HNEMD for silicene monolyer calculation, I faced the try and errors 
for choosing driving force parameter F_e.
In my experiences, depending on F_e, I got different thermal conductivities. 
I checked temperature and total energy of systems but it generally went stable.

Of course, I refered your paper 'PHYSICAL REVIEW B 99, 064308 (2019) that 
(F_e)(lambda) < 1 could be used. 
but it looked like I have to try several times or more.

How can I reduce these trials to choose  F_e? Is there know-how ?


Other related posts:

  • » [gpumd] Criteria for choosing F_e in HNEMD scheme. - 소순성