With the XP carrying the historian and the server with OPCHDA, we have Historian and related codes on the XP, and OPC codes on the Server. Should we have requested the OPC license with both the Server and the XP credentials and have an OPCHDA license code in each of the boxes? W C Ricker -----Original Message----- From: foxboro-bounce@xxxxxxxxxxxxx [mailto:foxboro-bounce@xxxxxxxxxxxxx] On Behalf Of Landry, Scott Sent: Tuesday, February 05, 2013 2:13 PM To: foxboro@xxxxxxxxxxxxx Subject: Re: [foxboro] AIM* OPCHDA Chris, fox is the correct user for the AIMHIS package on the Historian box. It does not matter what size (# of RTPs) your AIMHIS is, there is on;y one user. Assuming the historian box is the AIM package license retainer (has an_init.tcp file with AIMHIS and OPCHDA codes); Using apiadmin started from the Historian Box (AIM package license retainer ) 1. Create a user with the name of the IA letterbug of the box that the OPCHDA server (software package) is installed upon. It will end up being lowercase (that's OK) 2. under the packages Tab, give this user AIMAPI and OPCHDA packages (check them) delete any other user that has OPCHDA checked. (If this is the only OPCHDA) 3. Give this user full security permissions (read and write) 4. check the an_init.tcp file on the (AIM package license retainer) to see if your changes got applied 5. Restart AIMAPI ; Restart AIMOPCSERVER You also want to make sure that you know that the AIMOPCSERVER box was installed as Combined OPCDA and OPC HDA server to begin with. ________________________________________ From: foxboro-bounce@xxxxxxxxxxxxx [foxboro-bounce@xxxxxxxxxxxxx] On Behalf Of William C Ricker [wcricker@xxxxxxxxxxxxxxx] Sent: Tuesday, February 05, 2013 10:33 AM To: foxboro@xxxxxxxxxxxxx Subject: Re: [foxboro] AIM* OPCHDA We have that much in place. The OPCHDA runs as a service on a server box, but has no historian there. (one will be there in future). An XP based AW has a small historian and we wish to pull data from it through the OPC server. Applicable license codes are in. The OPC server does work quite nicely when asked to pick up real time data, but we've not managed to make it see our historian. We have connectivity between the Server and XP. OPCHDA is turned on for the <letterbug> user on the server. At the XP we have tried enabling AIMHIS for various users (as it is a 200 point historian we can only enable one user at a time). we have no luck. Mr. Peck suggested that the user name on the historian box should be the user which runs the OPC software on the server. If this runs as a service, should it be Administrator? System? the letterbug? Thanks for your help, W C Ricker -----Original Message----- From: foxboro-bounce@xxxxxxxxxxxxx [mailto:foxboro-bounce@xxxxxxxxxxxxx] On Behalf Of Landry, Scott Sent: Tuesday, February 05, 2013 11:02 AM To: foxboro@xxxxxxxxxxxxx Subject: Re: [foxboro] AIM* OPCHDA Chris, AIM*AT OPC Server Installation B0400DG – Rev B page 19 Before you can use the OPC server to communicate with AIM servers, each AIM Server must have an Invensys supplied license authorization code entered on the AIM Server. License codes are available to an unlimited number of AIM servers. The package code determines the type of connection authorized for the OPC server. The two types of package codes are as follows: ♦ The OPCDAO package code enables the OPC server to establish a connection for real-time data transfer. ♦ The OPCHDA package code enables the OPC server to establish a connection for both real-time and historical data transfer. In addition, the computer name of the station that is hosting the OPC server must be configured as a user name on the AIM server. NOTE If the station that hosts the OPC Server is an I/A Series station (AW70), then the computer name is the station letterbug name. Regards, Scott ________________________________________ From: foxboro-bounce@xxxxxxxxxxxxx [foxboro-bounce@xxxxxxxxxxxxx] On Behalf Of William C Ricker [wcricker@xxxxxxxxxxxxxxx] Sent: Monday, February 04, 2013 5:26 PM To: foxboro@xxxxxxxxxxxxx Subject: Re: [foxboro] AIM* OPCHDA RE: >User Name on the AIM OPC box must be listed as a package user in the AIM Historian Thanks, but more questions 'cause I can't get it to work . Does the name in the historian box need to be something like "fox" ? Does it include the station name ? If my OPC box has the server running as "SYSTEM", should that name be "SYSTEM" or "ADMINISTRATOR" ? Is your OPC running as a service ? W C Ricker _______________________________________________________________________ This mailing list is neither sponsored nor endorsed by Invensys Process Systems (formerly The Foxboro Company). Use the info you obtain here at your own risks. Read http://www.thecassandraproject.org/disclaimer.html foxboro mailing list: //www.freelists.org/list/foxboro to subscribe: mailto:foxboro-request@xxxxxxxxxxxxx?subject=join to unsubscribe: mailto:foxboro-request@xxxxxxxxxxxxx?subject=leave *** Confidentiality Notice: This e-mail, including any associated or attached files, is intended solely for the individual or entity to which it is addressed. This e-mail is confidential and may well also be legally privileged. If you have received it in error, you are on notice of its status. Please notify the sender immediately by reply e-mail and then delete this message from your system. Please do not copy it or use it for any purposes, or disclose its contents to any other person. This email comes from a division of the Invensys Group, owned by Invensys plc, which is a company registered in England and Wales with its registered office at 3rd Floor, 40 Grosvenor Place, London, SW1X 7AW (Registered number 166023). For a list of European legal entities within the Invensys Group, please select the Legal Entities link at invensys.com. You may contact Invensys plc on +44 (0)20 3155 1200 or e-mail reception@xxxxxxxxxxxx. This e-mail and any attachments thereto may be subject to the terms of any agreements between Invensys (and/or its subsidiaries and affiliates) and the recipient (and/or its subsidiaries and affiliates). _______________________________________________________________________ This mailing list is neither sponsored nor endorsed by Invensys Process Systems (formerly The Foxboro Company). Use the info you obtain here at your own risks. Read http://www.thecassandraproject.org/disclaimer.html foxboro mailing list: //www.freelists.org/list/foxboro to subscribe: mailto:foxboro-request@xxxxxxxxxxxxx?subject=join to unsubscribe: mailto:foxboro-request@xxxxxxxxxxxxx?subject=leave _______________________________________________________________________ This mailing list is neither sponsored nor endorsed by Invensys Process Systems (formerly The Foxboro Company). Use the info you obtain here at your own risks. Read http://www.thecassandraproject.org/disclaimer.html foxboro mailing list: //www.freelists.org/list/foxboro to subscribe: mailto:foxboro-request@xxxxxxxxxxxxx?subject=join to unsubscribe: mailto:foxboro-request@xxxxxxxxxxxxx?subject=leave *** Confidentiality Notice: This e-mail, including any associated or attached files, is intended solely for the individual or entity to which it is addressed. This e-mail is confidential and may well also be legally privileged. If you have received it in error, you are on notice of its status. Please notify the sender immediately by reply e-mail and then delete this message from your system. Please do not copy it or use it for any purposes, or disclose its contents to any other person. This email comes from a division of the Invensys Group, owned by Invensys plc, which is a company registered in England and Wales with its registered office at 3rd Floor, 40 Grosvenor Place, London, SW1X 7AW (Registered number 166023). For a list of European legal entities within the Invensys Group, please select the Legal Entities link at invensys.com. You may contact Invensys plc on +44 (0)20 3155 1200 or e-mail reception@xxxxxxxxxxxx. This e-mail and any attachments thereto may be subject to the terms of any agreements between Invensys (and/or its subsidiaries and affiliates) and the recipient (and/or its subsidiaries and affiliates). _______________________________________________________________________ This mailing list is neither sponsored nor endorsed by Invensys Process Systems (formerly The Foxboro Company). Use the info you obtain here at your own risks. Read http://www.thecassandraproject.org/disclaimer.html foxboro mailing list: //www.freelists.org/list/foxboro to subscribe: mailto:foxboro-request@xxxxxxxxxxxxx?subject=join to unsubscribe: mailto:foxboro-request@xxxxxxxxxxxxx?subject=leave _______________________________________________________________________ This mailing list is neither sponsored nor endorsed by Invensys Process Systems (formerly The Foxboro Company). Use the info you obtain here at your own risks. Read http://www.thecassandraproject.org/disclaimer.html foxboro mailing list: //www.freelists.org/list/foxboro to subscribe: mailto:foxboro-request@xxxxxxxxxxxxx?subject=join to unsubscribe: mailto:foxboro-request@xxxxxxxxxxxxx?subject=leave