[argyllcms] Re: targen error message

  • From: Graeme Gill <graeme@xxxxxxxxxxxxx>
  • To: argyllcms@xxxxxxxxxxxxx
  • Date: Tue, 06 Jul 2010 22:43:43 +1000

Tobias Huneke wrote:
targen -v -d2 -f420 -c precondition.mpp RGB_A4

But no ti1 is generated and targen returns the following error message:
"Error - No zero-dim surface combinations". What does this mean?

It means there is an internal geometric issue. It should work better
in the next release. You could try changing some of the parameters to
see if this dodges the problem. (I notice a bug in in the ink limit
handling from .mpp profiles - try -l300).

Graeme Gill.