[argyllcms] Re: profiling fluorescent (neon) colors

  • From: Ben Goren <ben@xxxxxxxxxxxxxxxx>
  • To: argyllcms@xxxxxxxxxxxxx
  • Date: Mon, 30 Sep 2019 21:36:19 -0700

On Sep 30, 2019, at 7:06 PM, Graeme Gill <graeme@xxxxxxxxxxxxx> wrote:


David Lewis wrote:

So as I understand your response, I would need to rig up some kind of mount
for the i1pro2 and another mount for each color patch in a dark room and
illuminate each patch with UV and take a reading - yes?

illuminate with the light you intend to view the final prints in,
assuming this is not the same as the native illuminant of the
i1pro2 (i.e not QH incandescent).

Of course, this is the practical answer. (Plenty technical challenges in making 
the measurements, but some ingenuity and craft techniques could overcome them. 
Don’t plan on a large patch count.)

I wonder, though...what are the chances for at elast some of the fluorescent 
patches to be brighter than the white patch? How would Argyll deal with that? 
And how would any other CMS deal with a profile created with such output values?

b&