[argyllcms] Re: colprof zero measurements

  • From: Graeme Gill <graeme@xxxxxxxxxxxxx>
  • To: argyllcms@xxxxxxxxxxxxx
  • Date: Tue, 29 Nov 2016 08:40:55 +1100

Michael Mauderer wrote:

I am manually preparing ti3 files that I am feeding into colprof to create a 
display profile.

For testing purposes, I have set up a list of artificial measurement data, 
where I match a
device RGB value with a corresponding CIE L*a*b* values. I am computing the 
matching pair,
by assuming the RGB value is an sRGB value, and converting it to CIE L*a*b*, 
so I'd expect
to get back a profile that closely matches the sRGB primaries and white point.

A way of checking your .ti3 file is to create a .ti1 file, and use fakeread
to generate the CIE data for an sRGB profile.
<http://www.argyllcms.com/doc/fakeread.html>

But without being able to see your .ti3 file, it's not possible to know
why it fails to work as you expect.

Пётр Б. wrote:
Please share your input file (you may use Ideone, Pastebin or whatever).

Yes.

Graeme Gill.


Other related posts: