[argyllcms] Re: [argyllcms]

  • From: Graeme Gill <graeme@xxxxxxxxxxxxx>
  • To: argyllcms@xxxxxxxxxxxxx
  • Date: Thu, 18 Nov 2010 08:28:41 +1100

andrzej duda wrote:

Using the same calibration file

I made two profiles

2. XYZ LUT

colprof -v -qh -aX -s "/Library/ColorSync/Profiles/Ekta Space PS 5, J.
Holmes.icc" -cpp -dmt -C -M -D "T966 A AdpHi B1 G2.15 Med LUT 14-11"

While the matrix profile is OK the LUT one gives very greenish dark
greys (0-30).
Is it normal or something went wrong?

Try an Lab cLUT profile. XYZ profiles may need more smoothing than
the default. It would help to send me the .ti3 file so that I
can see what the profile looks like.

Graeme Gill.