[argyllcms] Re: Using an i1 to measure FWA content?

  • From: Graeme Gill <graeme@xxxxxxxxxxxxx>
  • To: argyllcms@xxxxxxxxxxxxx
  • Date: Wed, 03 Feb 2010 16:03:05 +1100

Ben Goren wrote:
I had thought that the plot of the Hahnemuhle paper indicated the presence of 
FWA. But
your procedure seems to indicate it's negligible. Any chance you can offer your 
expert
opinion?

The only sure way is to use an instrument with/without a UV filter.

Argyll's FWA compensation is based on "typical" spectral behavior,
which isn't quite the same thing.

But looking at the behavior below 420nm which is fairly shallow, I would
guess this particular paper has small to no FWA.

Graeme Gill.