Tom Schumm wrote:
> So, lacking a spectormeter, do you recommend using no correction file at all 
> with this display/colorimeter combination? In other words, no correction 
> works 
> better than using the spectral file that comes with the i1Profiler software?

Hi,
        I think it would be silly to disregard the manufacturers
correction file if they have one for your display type, without
a strong reasons to do so such as measurements using a reference
instrument that prove the correction makes it less accurate.

Graeme Gill.