Hi Today I try to use ArgyllCMS 1.6.3 to create profile of RGB printer using ColorMunki spectrometer. Earlier I used 1.4.0 version and as was mentioned on this list, I slow down strip reading speed because of reduced scan rate in 1.6 ArgyllCMS. "Too many patches" errors occurs more frequently than on 1.4.0 but chart was scanned successfully. Checking of profile that was created from my measurements show large errors: Profile check complete, errors: max. = 54.739534, avg. = 3.634257, RMS = 7.913384 and after remeasuring of whole chart I got similar result: Profile check complete, errors: max. = 50.801395, avg. = 2.787503, RMS = 6.151080 After third measuring of this chart using 1.4.0 chartread and colprof I got completely different results: Profile check complete, errors: max. = 3.024343, avg. = 0.892335, RMS = 1.033585 So old 1.4.0 give in my case better results than 1.6.3 I do something wrong? I missed something? Here I post all logs and produced files (1.2 Mb): https://dl.dropboxusercontent.com/u/28502325/Argyll_logs.zip