[argyllcms] Re: How to make a .ti3 file

  • From: "pkr1979" <dmarc-noreply@xxxxxxxxxxxxx> (Redacted sender "pkr1979" for DMARC)
  • To: "argyllcms@xxxxxxxxxxxxx" <argyllcms@xxxxxxxxxxxxx>
  • Date: Wed, 25 Nov 2020 14:50:41 +0000

Thanks to both of you, particularly your patience.

However, it isnt working on my side. I also tried the files you sent me Miguel, 
and that isnt working either... whatever I do I get this:
scanin: Error - Scanin failed with code 0x10000004, read_elists: error opening 
match reference file 'it8.cht'

Here is the whole script:

peter@peter-desktop:~/Downloads/scanin-files$ scanin -v -dipna 
SMAScanMaster2.tif it8.cht R140603.txt diag-SMAScanMaster2.tif
TIFFFetchNormalTag: Warning, Incompatible type for "RichTIFFIPTC"; tag ignored.
Input file 'SMAScanMaster2.tif': w=2100, h=1496, d = 3, bpp = 8
Data input file 'R140603.txt'
Data output file 'SMAScanMaster2.ti3'
Chart reference file 'it8.cht'
Creating diagnostic tiff file 'diag-SMAScanMaster2.tif'
About to allocate scanrd_ object
Verbosity = 2, flags = 0x43a01
About to read input tiff file and discover groups
adivval = 1.000000
About to calculate edge lines
718 useful edges out of 2249
About to calculate rotation
Mean angle = -0.493277
Standard deviation = 4.233318
Robust mean angle = -0.014528 from 686 lines
About to calculate feature information
About to read reference feature information
About to write diag file
scanin: Error - Scanin failed with code 0x10000004, read_elists: error opening 
match reference file 'it8.cht'

Is the error due to some other stuff?

Cheers
Peter



‐‐‐‐‐‐‐ Original Message ‐‐‐‐‐‐‐
On Wednesday, November 25, 2020 2:56 PM, miguel medalha <medalist@xxxxxxx> 
wrote:



As mentioned Miguel, your target has very high resolution.
It seems this is an issue.
I've made a resize of your TIFF file to 2008 x 1342 pix @ 300dpi and now
it works fine! Without any additional magic with CHT, TXT or testchart
borders.

I just confirmed this. Even at 1200 ppi it works without a flaw.

While I considered the original resolution of the target way too high, I 
didn't expect this factor alone to cause such anomalies as the gross 
misplacement of the grid on the diag file. Turns out it did.

Thank you, Alexey!



Other related posts: