[argyllcms] Re: Help me format a printer calibration .ti3 file?

  • From: Graeme Gill <graeme@xxxxxxxxxxxxx>
  • To: argyllcms@xxxxxxxxxxxxx
  • Date: Tue, 5 Dec 2017 22:23:11 +1100

TONY ARNERICH wrote:

So - If I use COLOR_REP "iRGB_XYZ"

does that mean that my X, Y, Z values are then required, or could I include 
just the R, G,
B, SPEC_380, SPEC_390, ... etc.? The XYZ seems redundant to the "primal" 
spectral data
from which it was derived.

The required part is the "iRGB_" or the "RGB_" to tell it what device channels 
to expect.
It won't complain about the missing XYZ data if it can fall back on the 
spectral data.

[ BTW I'd probably print your 0/45 degree probe holder in black rather than red,
  to minimize the stray light bouncing off the paper and back into the 
measurement. ]

Cheers,

Graeme Gill.

Other related posts: