[argyllcms] Re: Compatibility with i1 (Eye One) Display Pro 3 retail and OEM?

  • From: Михаил Павлов <490540@xxxxxxxxx>
  • To: argyllcms@xxxxxxxxxxxxx
  • Date: Wed, 7 Mar 2012 17:24:03 +0400

On Wed, Mar 7, 2012 at 12:38 PM, Graeme Gill <graeme@xxxxxxxxxxxxx> wrote:

> Kristian Jörg wrote:
> > If needed I can assist with the mentioned debug settings on the i1d3
> with Argyll to help find a
> > method to read plasmas for Argyll profiling.
>
> I had another idea of how to calibrate the i1d3 to the refresh period,
> and after some effort, it seems to work when tested on CRT displays.
> I've no idea how well or badly it works on DPL or Plasma.
>
> I've updated this <http://www.argyllcms.com/disptools.win32.zip> for those
> interested - use -yr to select "refresh" type display, and -v will show
> what the calibration is doing. It will be in the next release too.
>
> It will only help if the display refresh period doesn't divide
> evenly into the default integration time of 200msec.
>
> Refresh rates that _do_ divide evenly into 200 msec,
> and for which this change is likely to make _no_ difference, is
> anything that's a multiple of 5Hz (ie. 25Hz, 50Hz, 60Hz, 75Hz, 100Hz etc.)
>
> [An interesting question is what is the period of Plasma Dithering is ? ]
>
> Graeme Gill.
>
>


-- 
С уважением,
Михаил Павлов