[argyllcms] Re: Cielab measurements doesn't work

  • From: Sylvain Ard <sylvain.ard@xxxxxxxxx>
  • To: argyllcms@xxxxxxxxxxxxx
  • Date: Mon, 2 May 2022 12:11:35 +0200

yes but ImageMagick uses QuantumRange instead of actual bit count

Sylvain Ard
0549507724
0778380991
sylvain.ard@xxxxxxxxx
http://sylvain-ard.fr
Entreprise individuelle SIRET : 80079243400022
Appt 26 Bât A Résidence Le Patio
83 rue de la Bugellerie
86000 Poitiers


Le lun. 2 mai 2022 à 11:40, Michael Perry <dmarc-noreply@xxxxxxxxxxxxx> a
écrit :

Wasn’t your scan an 8-bit scan though?

On 2 May 2022, at 07:07, Sylvain Ard <sylvain.ard@xxxxxxxxx> wrote:


Hello,
I finally succeeded by upgrading image magick with version HDRI 16 bits
and calculate the LAB values as follow from the LAB values of Image magick :
l:=l/QuantumRange
 a:=255*a/QuantumRange;
    if a>127 then
      a:=a-255;
 b:=255*b/QuantumRange;
    if b>127 then
      b:=b-255;
Sylvain Ard
0549507724
0778380991
sylvain.ard@xxxxxxxxx
http://sylvain-ard.fr
Entreprise individuelle SIRET : 80079243400022
Appt 26 Bât A Résidence Le Patio
83 rue de la Bugellerie
86000 Poitiers


Le lun. 2 mai 2022 à 07:23, Graeme Gill <graeme@xxxxxxxxxxxxx> a écrit :

Sylvain Ard wrote:

Hi,

hello, as I expected the measured CieLab values of the same photo of
the color chart have nothing to do with the theoretical CieLab
measurements!

It's hard to know what you mean by that, since you give no examples.

my commands chain is : scanin -dipn -G1.0 -v2 mire.tif ref\it8.cht
R202202.txt colprof -v
-D"Scanner A" -qm -ax -ua mire

Output is:
  Profile check complete, peak err = 6.512414, avg err = 1.252660

That's how accurate the profile will reproduce the target CIE values.

magick mire.tif +profile ICC -profile mire.icm -profile
Lab-D50-Identity-elle-V4.icc -define

It's hard to know what you are attempting with this, since I'm not
familiar with "magick" (presumably the "R" package ?).

Better using an ArgyllCMS utility if you can, then we can know exactly
what
is going on and are not trying to debug some other piece of software.
i.e.

  cctiff -ia mire.icc mire057.tif cie.tif

Some spot checking (using Photoshop histogram display, and translating
from 8 bit
0..255 to L*a*b*) shows delta E's that are in the expected range indicated
by the above colprof self fit error. i.e.:

        Patch   R202202.txt value       Raster L*a*b* value
        A4      22.59   33.49   12.73   22      33      15
        E14     70.27   40.06  -26.64   70      40      -26
        H15     85.55    1.08   72.02   85      1       73
        I19     31.76   25.31  -64.09   31      27      -66
        K18     49.24  -50.94   51.70   49      -50     51

so I can't understand where you think there's a problem.

Graeme Gill.