[argyllcms] Re: CMP Digital Target 3 chart recognition file

  • From: Pascal de Bruijn <pmjdebruijn@xxxxxxxxx>
  • To: argyllcms@xxxxxxxxxxxxx
  • Date: Mon, 15 Feb 2010 00:59:42 +0100

On Mon, Feb 15, 2010 at 12:34 AM, Graeme Gill <graeme@xxxxxxxxxxxxx> wrote:
> Pascal de Bruijn wrote:
>>
>> Yes, but does this matter? We want the reference file to match right?
>
> It matters because there wasn't a whole lot else to go on. While
> you may get a reference when you buy a chart, there isn't one
> on the website (that I can see), so it's kind of hard to know
> what to expect. The normal expectation would be that the reference
> patch ID's match what's printed on the chart. The worst
> possibility is that the reference chart varies in what
> it labels the patches, depending on whether the operator
> remembers to hit the right switch in X-Rite ProfileMaker
> when they measure it.
>
> Having a mismatch will then trigger various queries ("why is
> the patch labelling wrong") when someone looks at the scanin
> diagnostics, etc.

Yes, but now, chartreading always fails to recognize a certain set of patches...

You're introducing a certain problem, because otherwise we could maybe
hit another problem...

Regards,
Pascal de Bruijn

Other related posts: