Hello,

Rod or Sharon has just posted in the Machines & Hardware forum of AmayaUsers 
Discussion Boards under the title of Needle case not moving correctly after 
maintenance.

This thread is located at 
http://www.amayausers.com/discussion/showthread.php/6617-Needle-case-not-moving-correctly-after-maintenance

Here is the message that has just been posted:
***************
Were you very careful when putting the black cover back on and tighten the 
screws just enough that they are still slightly loose but the screws are in 
deep enough so they are flush with the plastic? After that, you move the 
needlecase so it can line it up so the needlebar studs can slide across evenly 
without getting hung up. THEN FINISH TIGHTENING THE SCREWS. If not, you risk 
the studs getting caught up and it could jam the needlecase or cut through the 
plastic and the cover will need replaced.
Sharon Springer (I hope this was understandable!)
***************

=========================================================== 