This message was posted by Rod or Sharon on AmayaUsers.com. PLEASE DO NOT REPLY VIA EMAIL. Instead, respond to the thread on the WEBSITE by clicking here: http://www.amayausers.com/boards/cgi-bin/ultimatebb.cgi?/topic/2/1250.html#000005 Gary, If this is only happening on the # 13 needle, it is not your timing....check the needle orientation carefully...make sure that it is either straight ahead or turned 5 to 10 degrees to the "right"....also, take off the red pinch roller and remove the inner threadfeed roller, wash them in med hot soapy water, relubricate and reinstall them. Becareful not to get any grease on the face of either roller or the thread will track off to the left side of the rollers and create a messy birdnest.... Rod Springer Amaya Tech & Trainer =========================================================== The AmayaUsers Mailing List Website: http://www.amayausers.com Discussion Board: http://www.amayausers.com/boards Subscribe/Unsubscribe: http://www.amayausers.com/list ===========================================================