This message was posted by Rod or Sharon on AmayaUsers.com. PLEASE DO NOT REPLY VIA EMAIL. Instead, respond to the thread on the WEBSITE by clicking here: http://www.amayausers.com/boards/ultimatebb.php?/topic/1/827.html#000001 Leighton & Rhonda, The first thing that you need to do is take off the needle plate and see if the selector and/or knife is working properly. The pushrod wire(s) may be broken or just come loose and the selector and/or knife may be out in the way of the needle path. You can go into Maintenance, Steppers and do the IN, OUT tabs to see if they fire and retract properly. This is a process of elimination....first things first.....something is getting in the way of the needle path....probably that is.... Rod Springer Amaya Tech & Trainer =========================================================== The AmayaUsers Mailing List Website: http://www.amayausers.com Discussion Board: http://www.amayausers.com/boards Subscribe/Unsubscribe: http://www.amayausers.com/list ===========================================================