[THIN] Re: Passthru Authentication - still prompting
- From: "Rick Mack" <Rick.Mack@xxxxxxxxxxxxxx>
- To: <thin@xxxxxxxxxxxxx>
- Date: Wed, 23 Feb 2005 16:34:28 +1000
Hi Ron,
For passthrough authenticaion to work, the single signon service has to be
running in each user's session. So if you look at the processes running inside
a user's desktop session, ssonsvr.exe has to be there. It captures the usr
credentials and passes them on to PN.
One possibility for your present problem is that installing/upgrading to
PNAgent 8.0 breaks single signon.
The simple fix is:
copy %systemroot%\system32\ctxrpc.dll "c:\program files\citrix\system32"
regards,
Rick
Ulrich Mack
Volante Systems
Level 2, 30 Little Cribb Street
Coronation Drive Office Park
Milton Qld 4064
tel: +61 7 32431847
fax: +61 7 32431992
rmack@xxxxxxxxxxxxxx
________________________________
From: thin-bounce@xxxxxxxxxxxxx on behalf of Ron Jameson
Sent: Wed 23/02/2005 4:16 PM
To: thin@xxxxxxxxxxxxx
Subject: [THIN] Re: Passthru Authentication - still prompting
checkbox is not checked in Connection Configuration which is why I am stumped
why it is not working.
Graphically challenged app is not really the app problem but is the seamless
problem (happens to any app (accounting programs)). When seamless, windows
appear slowly, when windowed it is fine. I just applied the R02 hotfix and
will have to check again if it changed. Also reinstalling PN8.1 on the login
front end 2003 terminal server.
Ron
________________________________
From: thin-bounce@xxxxxxxxxxxxx [mailto:thin-bounce@xxxxxxxxxxxxx] On Behalf Of
Walter, Chris
Sent: Tuesday, February 22, 2005 8:56 PM
To: 'thin@xxxxxxxxxxxxx'
Subject: [THIN] Re: Passthru Authentication - still prompting
If I understand everything correctly you are setting up everything in PN to use
passthrough authentication but it is not working when logging in through an ICA
session. If this is the case go into the Citrix connection configuration on
your Terminal server and make sure you don't have the checkbox checked for
'Prompt for password'. If this is on then you can't use passthrough
authentication.
As far as the graphically challenged app, need for info. What is the app?
Does it have a backend that is not on the same network as your Terminal server?
I would start my checking the performance on the terminal server and make sure
you don't have any duplex mismatches on the NIC.
Chris
-----Original Message-----
From: thin-bounce@xxxxxxxxxxxxx [mailto:thin-bounce@xxxxxxxxxxxxx] On Behalf Of
Ron Jameson
Sent: Tuesday, February 22, 2005 6:23 PM
To: thin@xxxxxxxxxxxxx
Subject: [THIN] Re: Passthru Authentication - still prompting
Joe - I am now using the desktop shortcut from the PN, I still cannot get the
pass thru to work....in the PN Application Set Settings login tab, if I select
pass thru login for local user, it prompts with the PN login info/pwd/domain
when running the app. When you enter it, it changes the login info to
User-Specific Credentials. The ICA Settings show pass thru enabled.
My other problem is trying to work on why the seamless app is graphically
challenged. Sluggish in seamless mode when I have tried turning off/on bitmap
cache & speedstream.
Ron
________________________________
From: thin-bounce@xxxxxxxxxxxxx [mailto:thin-bounce@xxxxxxxxxxxxx] On Behalf Of
Joe Shonk
Sent: Tuesday, February 22, 2005 5:08 PM
To: thin@xxxxxxxxxxxxx
Subject: [THIN] Re: Passthru Authentication - still prompting
Hmm... Not sure why you are creating custom .ica files. Simply install the PN
Agent Pass-through client (from the MFPS 3.0 install) and use that instead.
If you insist on using .ica and want Single Sign on, you will need to add an
entry that allow SSO via an ICA File.
Joe
________________________________
From: thin-bounce@xxxxxxxxxxxxx [mailto:thin-bounce@xxxxxxxxxxxxx] On Behalf Of
Ron Jameson
Sent: Tuesday, February 22, 2005 12:04 PM
To: thin@xxxxxxxxxxxxx
Subject: [THIN] Passthru Authentication - still prompting
Something is awry here that I could use help on from the experts. This is the
first citrix box install - we normally only do TS2000/2003 installs.
I have a citrix PS3ent app server publishing 5-10 apps to another TS2003 server
where users login to access the rest of the 10+ programs. I created the ICA
packaged .ica ini file for the app and put that icon on a users TS session
desktop folder - but when they click on it - it prompts for login to the
citrix. Am I missing an obvious here? The farm has pass thru set and I want
the login credentials of the users domain credentials from the TS session to
pass to the citrix app server seamlessly.
Here is some other oddities I could use some clarification on:
1) Using the same published app - the ica ini package opens the program fine
(from the TS2003 session) except for the login needed - it appears on the TS
desktop as a program running there. Users will NEVER know the
difference...they can minimize it, it only has one top window menu bar etc.
But, I did notice screen graphics a bit draggy as they seem to gradually appear
rather than snap.
Does the ICA engine create that much overhead to drag the program pull down
graphics etc vs. using PN to enter?
2) If from the users TS session, I go into PN and run the app thru there - it
passes thru fine with no login (once you enter your own login info in PN), but
the published app screen goes full screen with no TS users desktop. So, I
changed the published app to 1024x768 instead of full screen, but now it looks
like a session inside the TS session rather than a program. Program menus &
graphics in this method snap like they should.
I am still trying to test this various ways looking for what I need - which is
icons I can put on the TS2003 Sessions of the users (deployed via the existing
login script where program shortcuts are given to the users), the icon graphic
will need to be able to be changed to match the program (this may rule out the
ICA engine ini file), seamless login to the app with no secondary login
prompts, no drag in graphics and the program cannot have any extra screen menu
bars and appear like the program is running in the TS session.
Any advise would be a great help. Thanks.
Ron Jameson
Hamlin Technologies
#####################################################################################
This e-mail, including all attachments, may be confidential or privileged.
Confidentiality or privilege is not waived or lost because this e-mail has been
sent to you in error. If you are not the intended recipient any use,
disclosure or copying of this e-mail is prohibited. If you have received it in
error please notify the sender immediately by reply e-mail and destroy all
copies of this e-mail and any attachments. All liability for direct and
indirect loss arising from this e-mail and any attachments is hereby disclaimed
to the extent permitted by law.
#####################################################################################
Other related posts: