Had a dim blurry display and an audible "hiss" from inside around the circuit boards. Fix: Replace the "High Voltage bleeder-focus-G2 assembly" orig# A-17813-01. Used sub# A-17196-12 (A-17196-05 same). Cured the hiss (a corona discharge from the HV assy's body to the frame) and cured the dim/poor picture. Adjusted to best display. Note: MCM was the most expensive at almost fifty dollars higher! Used River Valley Electronics in Indiana 1-866-400-0778. -- Philip Bader, Jan Phyl TV Inc. 3420 Recker Hwy,Winter Haven, Fl. 33880 voice/fax: 863-299-8821 Established 1976 ------------------------------------------ To REMOVE your email address, click here: http://www.tech-assist.org/unsubb.html ------------------------------------------ ***NEW*** Tips Added Instantly!!!*** Submit Repair Tips here: http://www.tech-assist.org/secure/tip/