This Zenith Projection Model PV4661LK has had 2 replacement 9-1302 replacement modules installed and the unit may run for 1-3 days. I checked with the customer and she is not experiencing any arcing or flashing of one color before failure, so I suspect the CRTs are OK. Last time I was out I tapped the CRTs and the Hi Voltage Splitter Block, but did not get any results from that test. I suspect the HV Splitter Block, as the Horiz output always shorts. Who has seen and can verify the HV Block as a failure item?? I have seen maybe one and only one. Any other ideas why the Horiz output always shorts, even after replacing the module twice??? Damon Brunger damon101@xxxxxxxxxxxxxx Telrad Electronic Services Ft Wayne, IN 46815 ------------------------------------------ To REMOVE your email address, click here: http://www.tech-assist.org/unsubb.html To CHANGE your email address, click here: http://www.tech-assist.org/change.html ------------------------------------------ ***NEW*** Tips Added Instantly!!!*** Submit Repair Tips here: http://www.tech-assist.org/secure/tip/