Keith, This set will not start if it knows there is no vert sweep..check that first..Does the HV try to come up? if yes could be in HV shutdown.. and you have to unplug set to reset micro..Older models Z and A line had a leaky diode in shutdown circuit, off of pin 6 of flyback. Hope this helps Bob, Bobs tv... Worcester, ma main 508-853-1482 fax 508-853-1480 ----- Original Message ----- From: Keith Trumbla <ktrumbla@xxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Friday, May 24, 2002 12:48 PM Subject: [TechAssist] Zenith B25A11ZF 9-2108 SHUTDOWN > > The set runs for about 20 seconds then shutdowns down. Have to unplug to > restart. Model B25A11ZF ZENITH Chassis # 9-2108 . B+ is ok at 130 v > > Thanks > > Keith Trumbla > O/O B.E.M Electronics Est.1954 > 839 Ellice ave. > Winnipeg Manitoba, Canada R3G 0C3 > Ph.(204)775-2875 Fax(204) 774-9192 > Mail to : ktrumbla@xxxxxxxxxxx > > > _________________________________________________________________ > Get your FREE download of MSN Explorer at http://explorer.msn.com/intl.asp. > > ------------------------------------------ > To REMOVE your email address, click here: > http://www.tech-assist.org/unsubb.html > To CHANGE your email address, click here: > http://www.tech-assist.org/change.html > ------------------------------------------ > ***NEW*** Tips Added Instantly!!!*** > Submit Repair Tips here: > http://www.tech-assist.org/secure/tip/ > ------------------------------------------ To REMOVE your email address, click here: http://www.tech-assist.org/unsubb.html To CHANGE your email address, click here: http://www.tech-assist.org/change.html ------------------------------------------ ***NEW*** Tips Added Instantly!!!*** Submit Repair Tips here: http://www.tech-assist.org/secure/tip/