[TechAssist] Re: Zenith

Don,
Most of the time on these, you will find more than one pin shorted.

Jeff

FAX 1-413-280-0677
Intrepid Video & Electronics
501 Luther Rd
Harrisburg, PA 17111
717-909-8844
mailto:Jeff@xxxxxxxxxxxxxxxxxx  www.9-11-2001tragedy.com
www.intrepid-video.com www.tech-repair.net www.thetoolcaddy.com
----- Original Message -----
From: "Don" <tvgramps@xxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Sunday, January 06, 2002 7:53 PM
Subject: [TechAssist] Zenith


> Zenith  SS2504ew  9-1130 Came in with FX401 blown and two of the B+ diodes
> shorted CRX401/04
> Replaced diodes and fuse and at plug in it vented C432. replaced the cap
> then  on plug in the next time RX3433 and the same cap got very hot this
> uses a STR53041 is there any way to check the STR?  The HOT checks ok, am
> working without a schematic
>
>
> Don Reaka
>
>
> ------------------------------------------
> Help make your TechAssist database better!
> Submit your fixes here: http://circuitwork.com/techassist/tip/#tips
> ------------------------------------------
> To UNSUBSCRIBE your email address, click here:
> mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe
> Or send a BLANK email with unsubscribe in the
> SUBJECT field to the address above.
>
>

------------------------------------------
Help make your TechAssist database better!  
Submit your fixes here: http://circuitwork.com/techassist/tip/#tips
------------------------------------------
To UNSUBSCRIBE your email address, click here:
mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe
Or send a BLANK email with unsubscribe in the
SUBJECT field to the address above.