Do you get 120 volts AC across the motor leads? Change the motor Robert tvservice@xxxxxxxxxxxxx H & H Electronics Inc ----- Original Message ----- From: "Phil Bader" <tjanphyl@xxxxxxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Friday, June 11, 2004 12:25 PM Subject: [TechAssist] Whirlpool over-range M.wave/vent/light MH7110XBQ-O no mag-fan > This is the large over the range microwaves with the ventilation and > light underneath. > problem is I can set the cook time,say one minute, and push start. I > hear the hum of the mag, the timer display counts down, there is HV to > the magnetron, and the cup of water heats. > Just the blower fan that cools the mag tube is not running. It freely > spins, and otherwise seems OK. There is a 6 MFD square cap (start run?) > but it tested at 6 mfd. > I changed all fout safety switches around the door (no easy task) but no > help. > This is a Goldstar made oven. need some good M. wave techs out there! > Phil Bader > > -- > > Philip Bader > Jan Phyl TV Inc. (estab. 1976) > 3420 Recker Hwy. Winter Haven, Fl. 33880 > Fax (863) 299-8821 > email: tjanphyl@xxxxxxxxxxxxxxx > > > > -------------------------------------------------------------------------- --- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/