[TechAssist] Re: Whirlpool over-range M.wave/vent/light MH7110XBQ-O no mag-fan

  • From: "tvservice" <tvservice@xxxxxxxxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Fri, 11 Jun 2004 13:16:49 -0500

Do you get 120 volts AC across the motor leads?
Change the motor
Robert
tvservice@xxxxxxxxxxxxx
H & H Electronics Inc

----- Original Message ----- 
From: "Phil Bader" <tjanphyl@xxxxxxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Friday, June 11, 2004 12:25 PM
Subject: [TechAssist] Whirlpool over-range M.wave/vent/light MH7110XBQ-O no
mag-fan


> This is the large over the range microwaves with the ventilation and
> light underneath.
> problem is I can set the cook time,say one minute, and push start. I
> hear the hum of the mag, the timer display counts down, there is HV to
> the magnetron, and the cup of water heats.
> Just the  blower fan that cools the mag tube is not running. It freely
> spins, and otherwise seems OK. There is a 6 MFD square cap (start run?)
> but it tested at 6 mfd.
> I changed all fout safety switches around the door (no easy task) but no
> help.
> This is a Goldstar made oven. need some good M. wave techs out there!
> Phil Bader
>
> -- 
>
> Philip Bader
> Jan Phyl TV Inc. (estab. 1976)
> 3420 Recker Hwy. Winter Haven, Fl. 33880
> Fax (863) 299-8821
> email: tjanphyl@xxxxxxxxxxxxxxx
>
>
>
> --------------------------------------------------------------------------
---
> Lost Password:
> http://www.tech-assist.org  and select "Login Problems?".