SONY KV32XBR55: Replaced Q505(shorted), R571(open), IC531, L501(recommended replaced), and checked and resoldered D512(Checked Ok). No schematic. Still has bowed sides. Pincushion and Horiz.Size in service menu wont adjust (numbers change), all other adjustments work. If I jump across L501, I get almost full scan but I can still see that pincushion is out of alignment. Any thoughts to getting this set out of here would be greatly appreciated, Thanks, Neil TV Doctors 108 W. Main St. Monroe,Wa. 98272 360-794-6469 ***************************************** Help make your TechAssist online repair tips database better! Submit your fixes here: http://www.circuitwork.com/techassist/tip/#tips ***************************************** To UNSUBSCRIBE write to: techassist-request@xxxxxxxxxxxxx with unsubscribe in the subject line.