Thanks sorry I used a .1 ohm forgot to put the point in the e-mail. Shaun Advanced Electronics 224 West Riverview Ave. Fort Morgan, CO 80701 ----- Original Message ----- From: "Ron Miller d.b.a. Country TV" <rlmbkm@xxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Monday, October 25, 2004 2:25 PM Subject: [TechAssist] Re: Sony KV-32S22 DEAD > R607 is a .1 ohm not a one ohm, critical part value. > Bad connections anywhere in the deflection area can cause this problem.HTH > Country TV > Ron Miller > Inez, TX. 77968 > > ----- Original Message ----- > From: "Shaun" <satguy@xxxxxxxxxxxxx> > To: "tech" <techassist@xxxxxxxxxxxxx> > Sent: Monday, October 25, 2004 2:53 PM > Subject: [TechAssist] Sony KV-32S22 DEAD > > > > This set was dead I replaced Q502 (C5426), Q601 (C4834), Q602 (C4834) and > > R607 (1 ohm 1/2 watt). It runs now but I was curious if there were > anything > > else that causes these parts to go bad other than loose connections on the > > horz driver transformer? > > > > Thanks > > Shaun > > > > Advanced Electronics > > 224 West Riverview Ave. > > Fort Morgan, CO 80701 > > > > > > -------------------------------------------------------------------------- > --- > > Lost Password: > > http://www.tech-assist.org and select "Login Problems?". > > Email Archives: > > //www.freelists.org/archives/techassist/ > > > > > -------------------------------------------------------------------------- --- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/