The unit can be shutdown by protected. It can be the main board, check the convergence board. If the fuse on this board open.or the power supply board fails. I usually dissable the protected line that goes to power supply board. there is a connector that marks RM-12, E,RELAY,PRO. on power supply board.Or if the supply board fails you have to remove the board and test this board outside. This is the way I work . Be careful when you disable protected line It may burn something and you may find out the problem area if you can find out where the problem Dang tvcr ----- Original Message ----- From: Dave <tvman@xxxxxxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Monday, September 17, 2001 1:00 PM Subject: [TechAssist] Sony KP46V25 > SONY KP46V25 Relay clicks on high voltage comes up then set shuts down. Some times the red power light blinks some times it doesn't. Appreciate any help. > > Help make your TechAssist online repair tips > database better! Submit your fixes here: > http://www.circuitwork.com/techassist/tip/#tips > To unsubscribe write to: > techassist-request@xxxxxxxxxxxxx > with unsubscribe in the subject line. Help make your TechAssist online repair tips database better! Submit your fixes here: http://www.circuitwork.com/techassist/tip/#tips To unsubscribe write to: techassist-request@xxxxxxxxxxxxx with unsubscribe in the subject line.