Phil - I have the Sanyo manual on the DS31650 and it just shows the fuse as 4A, 125 volt. Nothing special. Max Bonnell Bonnell TV Robinson, IL Sender: techassist-bounce@xxxxxxxxxxxxx From: tjanphyl@xxxxxxxxxxxxxxx(Phil=A0Bader) Date: Sat, Jun 11, 2005, 1:31pm (CDT+1) To: techassist@xxxxxxxxxxxxx Subject: [TechAssist] Sanyo DS31650 dead, fix with replacing open 4A AC fuse? Reply=A0to: techassist@xxxxxxxxxxxxx We've had a lot of storms this month. I replaced the open 4A line fuse and set came up OK. (The STR30130, rectifiers,etc all OK). I put in a standard GMA4A fuse, and noticed from a cold start, the fuses element sagged a bit upon startup. Has anyone heard of the need for a time delay, or "slo-blo" 4A fuse needed in these 31" sets? Phil Bader -- Philip Bader Jan Phyl TV Inc. (estab. 1976) 3420 Recker Hwy. Winter Haven, Fl. 33880 Fax (863) 299-8821 email: tjanphyl@xxxxxxxxxxxxxxx ---------------------------------------------- ----------------------------------------------------------------------------- This Email List is Public. Remove: http://www.tech-assist.org/remove.htm Lost Password: http://www.tech-assist.org and select "Login Problems?". Appliance Repair List: http://www.tech-assist.org/secure/tip/chatjoin.htm#app Email Archives: //www.freelists.org/archives/techassist/