[TechAssist] Re: Rca Ctc177aa3 B+, B= Stanby and run

  • From: mebonnell@xxxxxxxxx (Old TV Man)
  • To: techassist@xxxxxxxxxxxxx
  • Date: Sun, 5 Jun 2005 19:09:07 -0500

Eric - I am looking at a CTC177AB.
I would say those voltages are OK. 
 
Max Bonnell
Bonnell TV
Robinson, IL

Sender: techassist-bounce@xxxxxxxxxxxxx From:
tvman@xxxxxxxxxxxxxxx(Eric=A0Manuel) Date: Sun, Jun 5, 2005, 9:13pm
(CDT+2:30) To: techassist@xxxxxxxxxxxxx Subject: [TechAssist] Rca
Ctc177aa3 B+, B+ Stanby and run Reply=A0to: techassist@xxxxxxxxxxxxx 

Hi need some help this set had reg shorted CR4106 shorted replaced it
set came on ok.I checked the B+ in standby it,s 149 volts in run it
drops to 142 volts.On pin#1 of the reg ic I have -40 volt and on pin#2 I
have -33 volts.I this ok the reg or the hot is not getting hot. Thanks
for looking,,,Eric 

Ps I also changed the 10 mfd 200 volt cap 
-- 
=A0=A0=A0=A0=A0=A0Eric
E M Electronics
Deer Lake Nfld
Canada
tvman@xxxxxxxxxxxxxxx 
---------------------------------------------- 

-----------------------------------------------------------------------------