Does anyone know how to run this chass on the bench without the front panel selector.It plugs into J3001 on mains.I tryed to remove the panel & what a pain in the ass.Looks like you have to remove the whole front unless there's a secret way of getting it out.This one mounts on the right front side of set??I want to T/S this unit on the bench.Orginally it had the HOT shorted,which I replaced with oem,after checking P/S, I fired it up & the HV was 38kv[too high] & Q4802=vert pin. trans smoked.Replaced pin diode=cr4402,&c4403=pin cap.Now the set is DOA?I want to bench test the chass.I should have my STBY volts with no panel plugged in,right??But when I want to turn it on how do I cheat this J3001,ie, which pins can I momentary short to start up the set??BTW i did replace all caps in P/S & the ic.All sweep caps were checked,aslo,the HOT & Damper are ok.All assistance welcome...TIA.... Don of HARTS-TVCR-ASC 9 Robert St,Oromocto,NB,Canada,E2V3N2 Tel-506-357-9785,Fax-506-357-6010 hartstv@xxxxxxxxxxx ***************************************************************************** CHECK OUT THE NEW CHATROOM! Just login and click on chat! http://www.tech-assist.org/secure/tip/main.htm The Tech Address Book: http://www.tech-assist.org/secure/tip/contact.htm Add a Repair Tip Here, or Change/Remove your Email Address: http://www.tech-assist.org/secure/tip/main.htm Lost Password: http://www.tech-assist.org and select "Lost your Login Info?". Email Archives: //www.freelists.org/archives/techassist/